Our Expertise
Upstream and downstream oil and gas assets face sour service, HIC, erosion and CUI (corrosion under insulation). Induscoat applies NACE-compliant coating systems, Arcor linings for pipe repair, tank floors and vessel internals. Our teams execute under ATEX constraints with full HSE plans, hot-work permits and confined-space protocols where required.
Key Challenges We Solve
- NACE-compliant pipeline coating
- Tank floor and vessel lining
- CUI (corrosion under insulation) mitigation
Equipment We Protect
- Above-ground storage tanks (AST) and tank floors
- Pressure vessels and separators
- Pipeline segments and risers
- Heat exchangers and tube-sheets
- Process piping under thermal insulation
Operational Constraints
- Sour service (H₂S) and HIC susceptibility of carbon steel
- Corrosion under insulation (CUI) in cyclic temperature service
- ATEX environment with strict hot-work and confined-space protocols
- NACE/AMPP and API 653 compliance for tank and pipeline integrity
Recommended Products & Brands
- NACE-compliant Arcor linings for tank floors and vessel internals
- Chester Molecular polymer coatings for CUI mitigation under insulation
- Chester Molecular repair mastic for flange face and heat exchanger tube-sheet
Types of Shutdowns
- Planned turnaround (every 4–6 years, 21–45 day shutdown)
- Tank inspection and cleaning outage (API 653, 10–20 year cycle)
- Emergency shutdown on leak detection, fire or gas alarm
Risks We Help You Avoid
- Environmental spill from tank floor or pipeline failure
- Asset loss from fire or explosion in ATEX service
- H₂S exposure and HIC-driven equipment failure
- Regulatory penalties for non-compliance with API 653 / NACE MR0175
Sector FAQ
Are your repairs compliant with API 510, API 653 and NACE?
Yes. Our composite repairs of pressure equipment follow ASME PCC-2 and ISO 24817, our storage-tank work meets API 653, and our coatings for H₂S service meet NACE MR0175. Every project is documented with procedure, qualification and quality control, for regulatory and insurance audits.
Can you repair a leak on a live pipeline?
Depending on the fluid, pressure and temperature, we apply ASME PCC-2-certified tolerant composite wraps on live or isolated lines. For high pressures and hazardous fluids (H₂S, hydrocarbons), shutdown remains necessary. We assess each case with your HSE team.
Which oil and gas sectors do you serve in Canada?
Refineries in Quebec and Ontario, storage terminals, transmission pipelines, natural-gas facilities, petrochemical plants and compressor stations. Our crews intervene in ATEX zones with work permits and HSE plans.